x이름 | GE 531X111PSHAPG2 모터 필드 제어/전원 공급 장치 | 제품 ID | 531x111pshapg2 |
---|---|---|---|
시리즈 | 531x | 제품 순 폭 | 100mm |
제품 순 높이 | 200mm | 제품 순 깊이/길이 | 330mm |
보증 | 1 년 | 제품 순 중량 | 2kg |
강조하다 | GE turbine control motor field,GE power supply 100mm x 200mm,GE motor control with warranty |
The GE 531X111PSHAPG2 is a Terminal Board Relay Card. Its core roles include supplying regulated DC power to power critical drive operations and integrating a pulse transformer dedicated to motor field circuitry—ensuring stable motor field current and supporting smooth drive-motor coordination.
As a specialized replacement part, it is strictly intended for installation and servicing by qualified, trained personnel. This requirement stems from the high-voltage nature of the drives it supports and the presence of moving parts that pose injury risks. Safety protocols for use mandate pre-installation area inspections (e.g., using only grounded extension cords, clearing trip hazards, ensuring dry floors), verification of 3-phase power cabling, and confirmation of functional emergency shutoff systems. Additionally, all service work must be conducted with a nearby trained assistant to address potential emergencies, aligning with industrial safety standards for high-risk equipment.
Attribute | Value |
---|---|
Name | GE 531X111PSHAPG2 Motor Field Control/Power Supply |
Product ID | 531X111PSHAPG2 |
Series | 531X |
Warranty | 1 Year |
Dimensions (W × H × D) | 100mm × 200mm × 330mm |
Weight | 2kg |
Power Supply Function: Delivers 5V DC, 15V DC, and 24V DC current essential for drive operation, plus integrates a pulse transformer to support motor field circuitry.
Safety-Centric Design: Classified as a specialized replacement part, requiring qualified installers/servicers to mitigate risks from high voltage and moving drive components.
Hazard Mitigation Protocols: Requires pre-installation area checks (grounded cords, dry floors, trip hazard removal) and power system verification (3-phase cabling, functional emergency shutoff) to ensure safe operation.
Emergency Support Requirement: Mandates a nearby, trained assistant during all service work, ensuring rapid response to potential accidents and aligning with industrial safety standards.